1
8
In Hold state
- if the weight is not changed, the current weight is not changed
- if the weight is changed(above the 10% of Max capa), the current weight is changed and
the Hold function is released
- Whenever unloaded states, the Hold function is released automatically
- Also you want to release the Hold function, have to press Hold key in unloaded
state certainly
- If Hold function is released, you can see the massage .
2. When the F5 is set to 01
The maximum value of weight is showed when the Hold key is pressed
If the Hold key is pressed once, the peak Hold function is started
If Hold function is released, you can see the massage .
If the Hold key is pressed again, the Hold function is released
If Hold function is released, you can see the massage .
(Ref> If the weight is 0 lb or 0 kg, this function is not operated.)
F 6
FUNCTION : Setting the time of Display off automatically
KEYS LCD SCREEN Setting value DESCRIPTION
00
01
02
03
Not use
Display all off in 3 minutes
Display all off in 6 minutes
Display all off in 9 minutes
Ref. 1. Operates the function of F6 which anything is set when the weight is in zero state.
2. The Display is ON when the weight is not in zero state or when the any key
In the remote controller and front cover is pressed