CAS CL5000J Series Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Balance de cuisine CAS CL5000J Series. CL5000 Series Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - CL5000 Series

CL5000 Series Network’s Manual (English) Rev. 2005. 07.12 F/W Version. 1.00, 1.01, 1.02, 1.03, 1.04, 1.08

Page 2 - Table of Contents

(Figure 3. Internet communication with PC and Scale) If you know the scales IP address and register into PC, you can access scale in

Page 3

E. Scale Configuration summery of scale network configuration 1) Set service type 3 at MENU 1911 and Scale ID. 2) Input IP, Gateway, Subnet mask

Page 4 - 1. Introduction

STEP2: Setting IP and Port F. Confirmation NOTE: If this figure appear on screen is normal. During the data transitions VFD

Page 5 - 1.1 Network card

2.2.2. Floating Clerk (Vender) A. Feature You can set Floating clerk set at MENU 1810, if Sale Mode is [1] REG: Ticket & Floating or [4] REG L

Page 6 - 1.2. Install Network card

E. Configuration This section explains how to configure master scale and slave scale(s). The following is an example of configuring of master an

Page 7

STEP2: Select service type as master STEP3: IP set-up There are three service types; [1] 1. Master [2] 2. Slave [3]

Page 8 - 2.1. General Terms

E.2. Setting first Slave scale STEP1: Set Scale as Floating clerk Mode STEP2: Setting Network Service Type 1810

Page 9 - 2.2.1. PC Control

STEP3: Set IP address STEP4: Set Remote IP E.3. Setting second Slave and others Repeat slave scale setting except, s

Page 10

2.3. Wireless LAN CL5000 Series supports Wireless LAN <Use of wireless network terms> SSID (Service Set Identifier): Name of Access Point

Page 11 - 1910

3. Application 3.1. Time Synchronize Step 1: Set Remote IP Set remote IP of master scale for PLU downloading NOTE: If you want to locate certain sc

Page 12 - 1940

Table of Contents 1. Introduction ...

Page 13

3.2. Remote Call PLU Step 1: Set Remote IP Set master scale’s IP address for Remote call PLU Step 2: Setting sync application

Page 14 - 1810

4. Protocol 4.1. General CL5000 has Prefix command to calculate data. The “C” has debug command. Network protocol has 4 types of command structur

Page 15 - 1911

Write command: EX) W<xx>:E<error code><0x0a> Error code table Read 80 Range Overflow 81 Access Deny 82 Mismach Receive Data or In

Page 16

4.2. PLU (Price Look up) ¾ Download W02A<pluno>,<deptno>L<data blocks size>:<data blocks><bcc> <data blocks>

Page 17 - 1914

Tare 13 L 4 Tare ID 12 B 1 %Tare 24 W 2 Tare % limit 23 W 2 Barcode ID 85 W 2 ProducedDate 20 W 2 Packed Date 18 W 2 Packed Time

Page 18 - 1916

¾ Upload 1. Uploading each PLU NOTE: You need to know PLU# and department# Each PLU Read R13F<plunumber>,<ptype><0x0a> &l

Page 19 - 3. Application

¾ Delete Thre are 3 ways to delete PLUs 1. Delete each PLU Send C<xx>F13,<pluno><0x0a> <pluno> := <2byte Deparment>

Page 20

4.2. Table 1 4.2.1. Department Department is component of name (description) and speed key. You can set up to 5 departments. ¾ Download W

Page 21 - 4. Protocol

¾ Upload Send R20F01,<id><0x0a> Sequencial Command R21F01,<id><0x0a> <id> :== <hexadecimal value> R21F01 … c

Page 22

4.3.2. Group Benifit: Grouped PLUs are useful to make a selective report information. Group is smallist report segment. ¾ Download W2

Page 23 - 4.2. PLU (Price Look up)

4.4. Store,Customer,Scroll Message and Clerk Table ... 44 4.4.1. Store

Page 24

4.3.3. Label Message ¾ Download W20F03,<id>L<data block size>:<data block> <data block> :==<description><error&

Page 25

4.3.4. Origin Downloading Origin country ¾ Download W20F04,<id>L<data block size>:<data block> <data block> :==&l

Page 26

4.3.5. PCS ¾ Download W20F05,<id>L<data block size>:<data block> <data block> :==<description><error> <de

Page 27 - 4.2. Table 1

4.3.6. Tax ¾ Download W20F06,<id>L<data block size>:<data block> <data block> :== <tax type><tax value><

Page 28 - Error :

4.3.7. Tare ¾ Download W20F07,<id>L<data block size>:<data block> <data block> :== <description><tare type>

Page 29 - 4.3.2. Group

4.3.8. Barcode Type You can set Barcode type for each PLUs. Also you need to select barcode type. (Register barcode type 1~99) ¾ Download W20F0

Page 31

4.3. Table2 Table2 is one of extension of PLU’s Table contains; Ingredient, Nutrition-Facts, Traceability (Country, Slaughter House, Cutting Hall)

Page 32 - 4.3.5. PCS

¾ Upload R30F01,<id><0x0a> R31F01,<id><0x0a> <id> :== more then 4Byte text lines 000100 is first 4letter=(“0001”) in

Page 33

Description <nutrifact-id> table 00 calories 01 Calories fat 02 Total Fat 03 Saturated Fat 04 Cholesterol 05 Sodium 06 Total Carbon 07 D

Page 34 - 4.3.7. Tare

1. Introduction Getting started This chapter introduces you to the network features about CL5000. CL5000 supports 2 unique communication modes.

Page 35 - 4.3.8. Barcode Type

4.3.3. Traceability This is Meet, Fish, other related product history coding. This code contains; Cutting hall, Slaughter house, bred count

Page 36

4.3.4. Country For traceability code you must insert country. You can set country code freely. Therefore need to maintain each country

Page 37 - 4.3.1. Ingredient

4.3.5. Slaughter House Traceability code element (you need to set country) ¾ Download W30F05,<id>L<data block size>:<data bloc

Page 38

4.3.6. Cutting Hall Traceability code element (need to set country) ¾ Download W30F06,<id>L<data block size>:<data block> &

Page 39

4.4. Store,Customer,Scroll Message and Clerk Table 4.4.1. Store Inset store data or delet ¾ Download W32F01,<id>L<data block size>

Page 40 - 4.3.3. Traceability

4.4.2. Customer Inset Customer information or delete Download W32F02,<id>L<data block size>:<data block> <data block> :

Page 41 - 4.3.4. Country

4.4.3. Scroll Message Insert Clerk information and delete ¾ Download W32F04,<id>L<data block size>:<data block> <data block

Page 42 - 4.3.5. Slaughter House

4.4.4. Clerk Insert Clerk information and delete ¾ Download W32F04,<id>L<data block size>:<data block> <data block> :=

Page 43 - 4.3.6. Cutting Hall

4.5. Discount Table Setting PLU Discount value ¾ Download W09F<dcno>,<mode>L<data block size>:<data block> <data blo

Page 44 - 4.4.1. Store

¾ Upload R09F<pluno>,Kdeptno><0x0a> R10F<xx>,<dc_no><0x0a> Description Upload method of <department number

Page 45 - 4.4.2. Customer

1.1 Network card You need network card for communication. We supports wire, and wireless network card. < Ethernet LAN Card > < Wirele

Page 46 - 4.4.3. Scroll Message

4.6. Report ¾ Upload R43F<period and part>,<6byte id><0x0a> <period and part>:== <period><part> <period>

Page 47 - 4.4.4. Clerk

Return W43F<period and part>,<6byte id>L<data block size>:<data block> <period and part>:== <period><part>

Page 48 - 4.5. Discount Table

04 Credit Card 05 Credit Note 06 Coupon 07 Bonus Point 08 Credit Sales 09 Change PLU report <id> : <plu save #

Page 49

Hourly report <id> : 1..24 (HR) <data block> := “M=”<transaction number>,<volume>. Clerk report <

Page 50 - 4.6. Report

4.7. Label and Image 4.7.1. Label format The maximum save Label format is 20. You can set Label ID, but Label ID 1~30 is already been set in scal

Page 51

4.7.3. Data File In CL5000 has Label data which contains; LFM and bitmap image A. LFM Data Structure LFM format contains Label Format. This inform

Page 52

B. Bitmap image Download structure NAME Type Bytes Description Format char 6 Label format Label Information Version char 2 Label Ver

Page 53

4.7.4. Transfer ¾ Download W06F<bin id>,<mode>L<data block size>:<data block> <bin id> := <4byte id> <mode

Page 54 - 4.7. Label and Image

Check and Apply This present setting label format not applied onto scale yet. This following command will switch to new set data. Check And

Page 55

4.8. Keypad 4.8.1. Speed Key Set ¾ Upload R04F21,<key no><0x0a> Speed Key set #1 Upload R04F22,<key no><0x0a> Speed

Page 56 - Download structure

1.2. Install Network card Install Ethernet LAN card 1) Turn power off and remove power cord 2) Remove Ethernet card cover 3) Insert Ethernet ca

Page 57 - 4.7.4. Transfer

4.8.2. Function Key setting ¾ Download W04F<keyhwid>,<key hwno>L<data size>:<data block><bcc> <keyhwid> := 0

Page 58

4.9. Other You can read scale’s date/time/current weight value Indicial setting – you can cheek firmware Version, History..., etc. 4.9.1. Date /

Page 59 - 4.8. Keypad

4.9.2. System Password ¾ System Password Change W45F02,00L<data block size>:<data block> <data block> := “P=”<string length

Page 60 - 4.8.2. Function Key setting

4.9.4. Weight Return current weight information ¾ Upload Send R45F04,00<0x0a> Receive W45F03,00L<data size>:<data><bc

Page 61 - 4.9. Other

4.10. PLU Field Control Set allowance or not allow PLU Field. Before using CL5000 set PLU item field. ¾ Download (setting) Send Setting W

Page 62 - 4.9.3. Scale Information

5. Internal Communication 5.1 Transaction Number Call up new Ticket Number from Remote Server i00F026,01 Return I00F036,L&l

Page 63 - 4.9.5. History

“F=” following each space data(binary, total length is 0x198) Each data are displayed “F=02.4C,0004:...” means, PLU Item <02> = means PLU N

Page 64 - 4.10. PLU Field Control

6.2. Department Ex1) Upload #8 Department Send : “R20F01,008<0x0a>” Receive: “W20F08,000L0024:^=03.*=01.$=0.&=0A0A032

Page 65 - 6.1. PLU

6.3. Ingredient Ex1) Upload #1 Ingredient Send : “R20F01,008<0x0a>” Receive: “W20F08,000L0024:^=03.*=01.$=0.&=0A0A032

Page 66

D=0A.BARCODE/01F=0D.DDIIIIIVPPPPCN=001.T=01.c” Description = “BARCODE/01” Format =”DDIIIIIVPPPPC” Barcode Format Number = 1 Type = 1 (UPC

Page 67 - 6.2. Department

Install Wireless LAN card 1) Turn power off and remove power cord 2) Remove Ethernet card cover 3) Insert Wireless LAN Card. i. Insert local wi

Page 68 - 6.4. Barcode Format

6.5. Discount Ex1) Upload PLU 1, Dept 1 of Discount information Send: “R09F0001,0001” Receive : No data “R09:E98<0x0a>” Rec

Page 69

Ex5) Download Discount data : deptno =1 pluno =2 Discount Type = 0x1c2b First Target = 100 First D

Page 70 - 6.5. Discount

6.6. Report Ex1 ) Upload Department 1, PLU 1 Send: “R09F0001,0001<0x0a>” Receive : “W09A0001,00L0072:^=03.*=01.$=0.&=0A0A0321.@=4F50.” “

Page 71

4. Reference Ref 1. Use of Terms Speed Key Set Number You can set 5 types of Speed key, this we call “SET NUMBER.” You can set for each depart

Page 72 - 6.7. Label and Image

Gateway A gateway can translate information between different network data formats or network architectures. It can translate TCP/IP

Page 73 - 4. Reference

2. Scale and System Configuration You can understand the concept of communication system and configuration. 2.1. General Terms CL5000 supports 3

Page 74

2.2. How to set Network method and scale 2.2.1. PC Control A. Feature You can control scale with PC or any computing environment such as, data tab

Commentaires sur ces manuels