CL5000 Series Network’s Manual (English) Rev. 2005. 07.12 F/W Version. 1.00, 1.01, 1.02, 1.03, 1.04, 1.08
(Figure 3. Internet communication with PC and Scale) If you know the scales IP address and register into PC, you can access scale in
E. Scale Configuration summery of scale network configuration 1) Set service type 3 at MENU 1911 and Scale ID. 2) Input IP, Gateway, Subnet mask
STEP2: Setting IP and Port F. Confirmation NOTE: If this figure appear on screen is normal. During the data transitions VFD
2.2.2. Floating Clerk (Vender) A. Feature You can set Floating clerk set at MENU 1810, if Sale Mode is [1] REG: Ticket & Floating or [4] REG L
E. Configuration This section explains how to configure master scale and slave scale(s). The following is an example of configuring of master an
STEP2: Select service type as master STEP3: IP set-up There are three service types; [1] 1. Master [2] 2. Slave [3]
E.2. Setting first Slave scale STEP1: Set Scale as Floating clerk Mode STEP2: Setting Network Service Type 1810
STEP3: Set IP address STEP4: Set Remote IP E.3. Setting second Slave and others Repeat slave scale setting except, s
2.3. Wireless LAN CL5000 Series supports Wireless LAN <Use of wireless network terms> SSID (Service Set Identifier): Name of Access Point
3. Application 3.1. Time Synchronize Step 1: Set Remote IP Set remote IP of master scale for PLU downloading NOTE: If you want to locate certain sc
Table of Contents 1. Introduction ...
3.2. Remote Call PLU Step 1: Set Remote IP Set master scale’s IP address for Remote call PLU Step 2: Setting sync application
4. Protocol 4.1. General CL5000 has Prefix command to calculate data. The “C” has debug command. Network protocol has 4 types of command structur
Write command: EX) W<xx>:E<error code><0x0a> Error code table Read 80 Range Overflow 81 Access Deny 82 Mismach Receive Data or In
4.2. PLU (Price Look up) ¾ Download W02A<pluno>,<deptno>L<data blocks size>:<data blocks><bcc> <data blocks>
Tare 13 L 4 Tare ID 12 B 1 %Tare 24 W 2 Tare % limit 23 W 2 Barcode ID 85 W 2 ProducedDate 20 W 2 Packed Date 18 W 2 Packed Time
¾ Upload 1. Uploading each PLU NOTE: You need to know PLU# and department# Each PLU Read R13F<plunumber>,<ptype><0x0a> &l
¾ Delete Thre are 3 ways to delete PLUs 1. Delete each PLU Send C<xx>F13,<pluno><0x0a> <pluno> := <2byte Deparment>
4.2. Table 1 4.2.1. Department Department is component of name (description) and speed key. You can set up to 5 departments. ¾ Download W
¾ Upload Send R20F01,<id><0x0a> Sequencial Command R21F01,<id><0x0a> <id> :== <hexadecimal value> R21F01 … c
4.3.2. Group Benifit: Grouped PLUs are useful to make a selective report information. Group is smallist report segment. ¾ Download W2
4.4. Store,Customer,Scroll Message and Clerk Table ... 44 4.4.1. Store
4.3.3. Label Message ¾ Download W20F03,<id>L<data block size>:<data block> <data block> :==<description><error&
4.3.4. Origin Downloading Origin country ¾ Download W20F04,<id>L<data block size>:<data block> <data block> :==&l
4.3.5. PCS ¾ Download W20F05,<id>L<data block size>:<data block> <data block> :==<description><error> <de
4.3.6. Tax ¾ Download W20F06,<id>L<data block size>:<data block> <data block> :== <tax type><tax value><
4.3.7. Tare ¾ Download W20F07,<id>L<data block size>:<data block> <data block> :== <description><tare type>
4.3.8. Barcode Type You can set Barcode type for each PLUs. Also you need to select barcode type. (Register barcode type 1~99) ¾ Download W20F0
4.3. Table2 Table2 is one of extension of PLU’s Table contains; Ingredient, Nutrition-Facts, Traceability (Country, Slaughter House, Cutting Hall)
¾ Upload R30F01,<id><0x0a> R31F01,<id><0x0a> <id> :== more then 4Byte text lines 000100 is first 4letter=(“0001”) in
Description <nutrifact-id> table 00 calories 01 Calories fat 02 Total Fat 03 Saturated Fat 04 Cholesterol 05 Sodium 06 Total Carbon 07 D
1. Introduction Getting started This chapter introduces you to the network features about CL5000. CL5000 supports 2 unique communication modes.
4.3.3. Traceability This is Meet, Fish, other related product history coding. This code contains; Cutting hall, Slaughter house, bred count
4.3.4. Country For traceability code you must insert country. You can set country code freely. Therefore need to maintain each country
4.3.5. Slaughter House Traceability code element (you need to set country) ¾ Download W30F05,<id>L<data block size>:<data bloc
4.3.6. Cutting Hall Traceability code element (need to set country) ¾ Download W30F06,<id>L<data block size>:<data block> &
4.4. Store,Customer,Scroll Message and Clerk Table 4.4.1. Store Inset store data or delet ¾ Download W32F01,<id>L<data block size>
4.4.2. Customer Inset Customer information or delete Download W32F02,<id>L<data block size>:<data block> <data block> :
4.4.3. Scroll Message Insert Clerk information and delete ¾ Download W32F04,<id>L<data block size>:<data block> <data block
4.4.4. Clerk Insert Clerk information and delete ¾ Download W32F04,<id>L<data block size>:<data block> <data block> :=
4.5. Discount Table Setting PLU Discount value ¾ Download W09F<dcno>,<mode>L<data block size>:<data block> <data blo
¾ Upload R09F<pluno>,Kdeptno><0x0a> R10F<xx>,<dc_no><0x0a> Description Upload method of <department number
1.1 Network card You need network card for communication. We supports wire, and wireless network card. < Ethernet LAN Card > < Wirele
4.6. Report ¾ Upload R43F<period and part>,<6byte id><0x0a> <period and part>:== <period><part> <period>
Return W43F<period and part>,<6byte id>L<data block size>:<data block> <period and part>:== <period><part>
04 Credit Card 05 Credit Note 06 Coupon 07 Bonus Point 08 Credit Sales 09 Change PLU report <id> : <plu save #
Hourly report <id> : 1..24 (HR) <data block> := “M=”<transaction number>,<volume>. Clerk report <
4.7. Label and Image 4.7.1. Label format The maximum save Label format is 20. You can set Label ID, but Label ID 1~30 is already been set in scal
4.7.3. Data File In CL5000 has Label data which contains; LFM and bitmap image A. LFM Data Structure LFM format contains Label Format. This inform
B. Bitmap image Download structure NAME Type Bytes Description Format char 6 Label format Label Information Version char 2 Label Ver
4.7.4. Transfer ¾ Download W06F<bin id>,<mode>L<data block size>:<data block> <bin id> := <4byte id> <mode
Check and Apply This present setting label format not applied onto scale yet. This following command will switch to new set data. Check And
4.8. Keypad 4.8.1. Speed Key Set ¾ Upload R04F21,<key no><0x0a> Speed Key set #1 Upload R04F22,<key no><0x0a> Speed
1.2. Install Network card Install Ethernet LAN card 1) Turn power off and remove power cord 2) Remove Ethernet card cover 3) Insert Ethernet ca
4.8.2. Function Key setting ¾ Download W04F<keyhwid>,<key hwno>L<data size>:<data block><bcc> <keyhwid> := 0
4.9. Other You can read scale’s date/time/current weight value Indicial setting – you can cheek firmware Version, History..., etc. 4.9.1. Date /
4.9.2. System Password ¾ System Password Change W45F02,00L<data block size>:<data block> <data block> := “P=”<string length
4.9.4. Weight Return current weight information ¾ Upload Send R45F04,00<0x0a> Receive W45F03,00L<data size>:<data><bc
4.10. PLU Field Control Set allowance or not allow PLU Field. Before using CL5000 set PLU item field. ¾ Download (setting) Send Setting W
5. Internal Communication 5.1 Transaction Number Call up new Ticket Number from Remote Server i00F026,01 Return I00F036,L&l
“F=” following each space data(binary, total length is 0x198) Each data are displayed “F=02.4C,0004:...” means, PLU Item <02> = means PLU N
6.2. Department Ex1) Upload #8 Department Send : “R20F01,008<0x0a>” Receive: “W20F08,000L0024:^=03.*=01.$=0.&=0A0A032
6.3. Ingredient Ex1) Upload #1 Ingredient Send : “R20F01,008<0x0a>” Receive: “W20F08,000L0024:^=03.*=01.$=0.&=0A0A032
D=0A.BARCODE/01F=0D.DDIIIIIVPPPPCN=001.T=01.c” Description = “BARCODE/01” Format =”DDIIIIIVPPPPC” Barcode Format Number = 1 Type = 1 (UPC
Install Wireless LAN card 1) Turn power off and remove power cord 2) Remove Ethernet card cover 3) Insert Wireless LAN Card. i. Insert local wi
6.5. Discount Ex1) Upload PLU 1, Dept 1 of Discount information Send: “R09F0001,0001” Receive : No data “R09:E98<0x0a>” Rec
Ex5) Download Discount data : deptno =1 pluno =2 Discount Type = 0x1c2b First Target = 100 First D
6.6. Report Ex1 ) Upload Department 1, PLU 1 Send: “R09F0001,0001<0x0a>” Receive : “W09A0001,00L0072:^=03.*=01.$=0.&=0A0A0321.@=4F50.” “
4. Reference Ref 1. Use of Terms Speed Key Set Number You can set 5 types of Speed key, this we call “SET NUMBER.” You can set for each depart
Gateway A gateway can translate information between different network data formats or network architectures. It can translate TCP/IP
2. Scale and System Configuration You can understand the concept of communication system and configuration. 2.1. General Terms CL5000 supports 3
2.2. How to set Network method and scale 2.2.1. PC Control A. Feature You can control scale with PC or any computing environment such as, data tab